Arpa, Sitti
DiscoverSys Inc

Published : 2 Documents
Articles

Found 2 Documents
Search

The effect of fabrication techniques of temporary crowns on the gingiva health Machmud, Edy; Hasminar, Hasminar; Arafi, Armawati; Kristianti, Catarina A.; Arpa, Sitti; Amiruddin, Maqfirah; Jubhari, Eri H.
Journal of Dentomaxillofacial Science Vol 4, No 3 (2019): (Available online: 1 December 2019)
Publisher : DiscoverSys Inc

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.15562/jdmfs.v0i0.853

Abstract

Objective: To determine the effect of manufacturing technique of temporary imitative crown on the gingiva health.Material and Methods: The clinical experimental study was conducted on 10 samples for each the manufacturing technique of temporary imitative crowns. On sample we conduct clinical examination by using plaque and gingival indexes, as well as DHE and scaling at the beginning of the study. And then we count the number of bacterial colonies by using swab method on the cervical part of the provisory. Data were analyzed by chi-square test.Results: There was an effect between the manufacturing technique of temporary imitative crown with plaque and gingival indexes and there was a significant correlation between the manufacturing techniques of provisory on the gingiva health (p<0.05).Conclusion: There was an effect between the manufacturing techniques of the temporary imitative crown on the gingival health. The manufacturing technique of indirect-direct has minimum effect on the gingival health.
Mandibular implant-retained overdenture with magnets in total edentulous patients (case report) Machmud, Edy; Arpa, Sitti
Journal of Case Reports in Dental Medicine Vol 1, No 1 (2019)
Publisher : Journal of Case Reports in Dental Medicine

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (785.022 KB)

Abstract

Objective: According to the manufacture, fewer than 1 in 10 capsule associated with overdentures on natural teeth separated from the denture base during an 8-year clinical trial; more interestingly, none experience loss of magnetic attraction.Methods: A 50 year old female patient came to Dental Hospital Makassar Hasanuddin University wanted to fix a loose denture, which has been used for 9 years. Chief complaint was a mobile mandibular denture. Treatment for the restoration of oral function, including mastication, using mandibular implant-retained overdenture with magnets in total edentulous. Implant supported retained with magnetic attachment constitute an accurate and predictable treatment option and achieve a higher patients satisfaction.Results: The surface of both magnet and attachment keeper were coated with titanium nitride (TiN). Self-curing resin was used for luting between  magnets and denture base resin.Conclusion: Magnetic attachments can be used to retain mandibular implant overdenture.Key words: Implant supported overdenture with magnets, resorbed alveolar ridge, total edentulous