All Journal Jurnal MEKANIKAL Jurnal Kanun bionature Jurnal Online Mahasiswa (JOM) Bidang Keguruan dan Ilmu Pendidikan TARBAWIYAH Jurnal Antropologi: Isu-Isu Sosial budaya JOURNAL OF EDUCATION SCIENCE Journal Of Syiah Kuala Dentistry Society Perspektif Jurnal Pendidikan: Teori, Penelitian, dan Pengembangan Jurnal Bindo Sastra Shautut Tarbiyah JST ( Jurnal Sains Terapan ) Jurnal Pendidikan Islam Indonesia Jurnal INSYPRO (Information System and Processing) Eralingua : Jurnal Pendidikan Bahasa Asing dan Sastra Hasanuddin Law Review SUARA GURU Varia Justicia Jurnal Keteknikan dan Sains (JUTEKS) al-fikrah: Jurnal Manajemen Pendidikan KACANEGARA Jurnal Pengabdian pada Masyarakat Jurnal Kolaboratif Sains CARADDE: Jurnal Pengabdian Kepada Masyarakat At-Tafkir JMM UNRAM - MASTER OF MANAGEMENT JOURNAL TAHKIM JSHP (Jurnal Sosial Humaniora dan Pendidikan) IJISCS (International Journal Of Information System and Computer Science) Tarbawiyah Jurnal Ilmiah Pendidikan Jurnal Nasional Teknik Elektro dan Teknologi Informasi (JNTETI) Nizham Journal of Islamic Studies Serambi Saintia : Jurnal Sains dan Aplikasi JURNAL ILMIAH ILMU KOMPUTER MAWA'IZH: JURNAL DAKWAH DAN PENGEMBANGAN SOSIAL KEMANUSIAAN Jurnal Maternitas Kebidanan Jurnal Keperawatan Priority Jurnal Akta Yudisia DEDIKASI: Jurnal Pengabdian Masyarakat EPI International Journal of Engineering Jurnal Sains Riset Jurnal Borneo Humaniora Jurnal Sosial Humaniora Sigli AL-ADABIYA: Jurnal Kebudayaan dan Keagamaan Jurnal Himasapta BirLE
Articles

Found 4 Documents
Search
Journal : Jurnal MEKANIKAL

ANALISIS PENGARUH KUALITAS UAP RATA-RATA TERHADAP KOEFISIEN PERPINDAHAN PANAS RATA-RATA PADA PIPA KAPILER DI MESIN REFRIGERASI FOCUS 808 Basri, Basri
Jurnal MEKANIKAL Vol 2, No 2 (2011)
Publisher : Jurnal MEKANIKAL

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (130.402 KB)

Abstract

This study aimed to obtain the influence of the average steam quality of heat transfer coefficient on average that occurs in the capillary tube and the relationship between average steam qualities with heat transfer coefficient on average in the capillary tube. This research was conducted at the University Engineering Laboratory Cooling Tadulako. Test methods used in the study is testing them experimentally. Data were collected by taking a direct test data on test equipment. Data were analyzed theoretically based on the experimental test data. The results of this study, namely that the refrigerant mass flow rate affect the heat transfer coefficient on average that occurs in the capillary tube is in the form of equation is hcm = 59569.78 xm^1.52
STUDI KAITAN PARAMETER PENGEREMAN DENGAN BEBAN DINAMIS PADA KENDARAAN Mustofa, Mustofa; Naharuddin, Naharuddin; Basri, Basri
Jurnal MEKANIKAL Vol 1, No 1 (2010)
Publisher : Jurnal MEKANIKAL

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (280.185 KB)

Abstract

This research aims to study influence of parameters of brakes components and dynamic weight on vehicle. Car of Suzuki Katana is taken as sample of a braking study. Data was procured in the mechanical engineering laboratory of Tadulako University and in the Duty Communication of District of Kayumalue in North Palu. Result of calculation indicates that oil pressure put on the brakes pw (kg/cm2), tread force of a brake pedal Q (kg) and dynamic weight of vehicle (kg) both front wheels and rear wheels weights are parameters which are significant in studying the brakes system.
ANALISIS PENGARUH LAJU ALIRAN MASSA TERHADAP KOEFISIEN PERPINDAHAN PANAS RATA-RATA PADA PIPA KAPILER DI MESIN REFRIGERASI FOCUS 808 Basri, Basri
Jurnal MEKANIKAL Vol 2, No 1 (2011)
Publisher : Jurnal MEKANIKAL

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (138.607 KB)

Abstract

This study aimed to obtain the influence of the mass flow rate of heat transfer coefficient on average that occurs in the capillary tube and the relationship between mass flow with heat transfer coefficient on average in the capillary tube. This research was conducted at the University Engineering Laboratory Cooling Tadulako. Test methods used in the study is testing them experimentally. Data were collected by taking a direct test data on test equipment. Data were analyzed theoretically based on the experimental test data. The results of this study, namely that the refrigerant mass flow rate affect the heat transfer coefficient on average that occurs in the capillary tube is in the form of equation (see full text)    
PENGARUH PENAMBAHAN SILINDER PEJAL PADA ALAT PENUKAR KALOR PIPA GANDA Putra, Indra Pertama; Marsan, Kennedy; Basri, Basri
Jurnal MEKANIKAL Vol 9, No 1 (2018): Jurnal Mekanikal Januari 2018
Publisher : Jurnal MEKANIKAL

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (625.08 KB)

Abstract

Penelitian ini bertujuan mengetahui efektivitas alat penukar kalor jenis pipa ganda dengan penambahan silinder pejal dan variasi laju aliran (debit). Pengujian dilaksanakan tanpa penambahan silinder pejal (standar) dan penambahan silinder pejal dengan variasi diameter 6 mm, 8 mm, dan 10 mm. Variasi debit pada sisi air panas 0,1 gal/min dan 0,2 gal/min sedangkan pada sisi air dingin dipertahankan 6 gal/min. Nilai efektivitas alat penukar kalor pipa ganda tanpa silinder pejal pada debit 0,1 gal/min yaitu 62,39%, yang kemudian mengalami peningkatan hingga 79,33% pada penambahan silinder pejal diameter10 mm. Sedangkan, pada variasi debit 0,2 gal/min nilai efektivitas alat penukar kalor pipa ganda tanpa penambahan silinder pejal yaitu 48,46% yang kemudian mengalami peningkatan hingga 76,8% pada penambahan silinder pejal diameter10 mm. Kata Kunci : alat penukar kalor,  pipa ganda, debit, diameter silinder pejal, efektivitas