Abstract

A study of the assessment criteria covers the synthesis and characterization of agent and test their biological effectiveness as boron neutron capture therapy (BNCT) agents in cancer treatment. The cellular uptake of this agent into the glioblastoma cells was assessed by boron analysis (ICP-MS) and by fluorescence imaging (confocal microscopy). The agent enters the glioblastoma cells exhibiting a similar profile, i.e., preferential accumulation in the cytoskeleton and membranes and a low cytotoxic activity (IC50 values higher than 200 μM). The cytotoxic activity and cellular morphological alterations after neutron irradiation in the Research Reactor (>107 neutrons cm−2 s−1) were assessed by the MTT assay and by electron microscopy (TEM). Post neutron irradiation revealed that BNCT has a higher cytotoxic effect on the glioblastoma cells. Results provide a strong rationale for considering one of these compounds as a lead candidate for a new BNCT agent.
Assessment of Analytical Instrumentation for Boron Measurement in BNCT System Triatmoko, Isman Mulyadi; Sutjipto, Sutjipto
Indonesian Journal of Physics and Nuclear Applications Vol 2 No 1 (2017)
Publisher : Fakultas Sains dan Matematika Universitas Kristen Satya Wacana

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (866.12 KB) | DOI: 10.24246/ijpna.v2i1.20-33

Abstract

The methods boron measurement in BNCT system has generally progressed with developments in analytical instrumentation. Spectrophotometric methods remained the methods of choice for most routine applications until the development of ICP-OES. ICP-OES was also not adequately sensitive for nutritional and medical research involving animal tissues that are naturally low in boron (B). The development of plasma-source MS (e.g., ICP-MS) not only has overcome most of these drawbacks, but also its capability of measuring B isotopes. The application of nuclear reaction methods (mainly prompt-γ spectrometry) has remained limited to some specialized fields. The validity and comparability of three different analytical techniques (QNCR, PGAA, and ICP-MS) for boron measurement in biological samples and application of these methods for examination of blood and tissue samples from a clinical study on boron uptake in blood, tissue, and neoplastic tissue, after infusion of BPA. The PET-based approach to TPS has been applied in BDTPS and a preliminary evaluation of the correct operation has been performed using a heterogeneous boron phantom, called HEBOM. The validation has been accompanied by calculations done with SERA, following the standard approach. BDTPS needs further in vivo experimental validations.